Provides an overview of the iCAP 6000 Series ICP-OES Spectrometer and its core components.
Details the various manuals and help systems available for the iCAP 6000.
Details the services and environment required before instrument installation.
Describes the assembly of glassware for the sample introduction system.
Instructions for correctly assembling the torch component of the instrument.
Guidance on inserting the torch assembly into the instrument's torch box.
Steps for connecting the spray chamber and nebuliser for sample introduction.
Details on connecting sample and drain tubing to the peristaltic pump.
Procedure for aligning the torch for optimal sensitivity and results.
Process for automatically adjusting analyte wavelengths for accurate measurements.
General setup procedures for the sample introduction system.
Information on available peristaltic pump tubing options for different sample types.
Explanation of internal standards and their use in correcting signal intensity.
Details on hardware configurations required for specific analytical applications.
Steps to create a new local database for storing iCAP results.
Instructions for establishing a connection to a database server.
Steps to prepare the instrument and system for analytical use.
Procedure for safely shutting down the iCAP instrument.
Overview of analytical operations and method verification.
Parameters affecting data and how to optimise them for analysis.
Steps to begin using the instrument for analysis.
Detailed sequence of steps for operating the iCAP instrument.
Guide to performing a simple analysis and creating a method.
Steps involved in creating a new analytical method within the iTEVA software.
Instructions on how to run an analysis after creating a method.
Procedure for optimizing the spectrometer and positioning lines on the detector.
Steps to calibrate the method using blank and standard samples.
How to analyze unknown samples after the method has been calibrated.
Procedure for safely shutting down the iCAP instrument and its components.
Guidelines for keeping the iCAP 6000 instrument clean.
Procedures for cleaning and decontaminating the sample introduction system.
Detailed instructions for cleaning the torch assembly.
Steps for cleaning the spray chamber to maintain performance.
Procedures for cleaning the nebuliser to prevent blockages.
Instructions for cleaning the Purged Optical Path (POP) window.
Information on periodic checks and maintenance for performance.
Maintenance requirements for the water chiller unit.
Guidance on checking and maintaining gas filters for optimal performance.
General safety information for the iCAP 6000 instrument.
Introduction to safety precautions and personnel qualifications.
Details general and specific safety procedures and symbols.
Safety guidelines related to electrical connections and power.
Procedures for cleaning and decontaminating equipment, especially after spills.
Actions to take when safety protection features are impaired.
Information regarding Waste Electrical & Electronic Equipment compliance.
Notices regarding CE marking and compliance with European directives.