EasyManua.ls Logo

Thermo LabSystems Multiskan EX - Page 117

Default Icon
314 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Driving the plate our and initializing the starting column so that the
absolute starting column is
j.
Example:
O
CF
S2
LF
M4
LF
(columns
2,3,4
and
5
are measured)
XI
Set shaking speed to maximum. (This speed
is
selected as
a
default.)
X2
Set shaking speed to
66
%of maximum
X3
Set
shaking speed to
33
%of maximum
Shaking of the microplate,
n
in shaking time in seconds (n
=
0060)
Example: Shaking of
5
s
is
entered as
205.
Date and time.
N
Serial number.
V
Version number of the sotlware.
Returning to the keypad use.
Commands
T,
Nand
V
can also
be
used while the instrument displays
RE
Each command must
be
terminated by
CF.
Multiskan
EX
disregards spaces before the command. Up to
48
extra
characters between the command and
LF
will be ignored.
Acknowled~ement Messges in Module
I:
Multiskan EXacknowledges each command by sending a message. The following messages are used:
OK
The action has been successfully performed.
ERI
Error
(see section
5.
Trouble shooting)
ER?
An
invalid command that Multiskan EX was not able lo understand.
The
P
and
PM
commands are acknowledged by sending values
of
the measured wells.
Data
flow
to
the
computer is
a
follows:
DATA DATA BATA DATA DATA DATA DATA DATA DATA DATA DATA DATA
CRLF
DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA
CRLF
DATA DATA DATA DATA DATA DATA DATA DATA BATA DATA DATA DATA
CRLF
DATA DATA DATA DATA BATA DATA BATA DATA DATA BATA DATA BATA
CRLF
DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA
CRLF
-
DATA DATA BATA DATA DATA DATA DATA DATA DATA DATA DATA DATA
CR&F
DATA BATA DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA
CRLF
DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA
CaLF
where
C
=
carriage
return
and line feed
D
=
6
characters, where the first character can
be
a
space
or a minus sign and the remainder
c
digits or decimal points
The
V
command sends the test
MULTISKAN
EX
VERSION
X.V
(where
X
can
be
1...9
and
Y
can have
%
So
8
characters) as acknowledgement message.
The
T
command
is
acknowledged by sending
XX.
(example:
19.
MAR
1991
20:42:03).
The
N
command is acknowledged
by
sending SERIALX
...
X,
where
X
can be
0...9,
-or
space
(example:
SERIAL352-00001).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Related product manuals