START THE BOILER: On the start display screen press the button
ON to start the boiler.
In the user menu, this button is used to activate certain functions
(eg. Activate heating circuit 1) .
SWITCH OFF BOILER :
On the start display screen press button OFF to stop the boiler.
In the user menu, this button is used to deactivate certain functions
(eg. Deactivate heating circuit 1) .
When you press the ignition key, the grate and pipe exchanger cleaning phase begins. The
cleaning phase ends when the grid makes three full turns. Then the phase of the ignition
begins. The dispenser for the pellet, heater and suction fan for flue gases are than in
operation. The dispenser performs the initial insertion of pellet into the burner for
combustion. At the same time, the heater is switched on and the pellets are burned, while
the suction fan performs the required combustion pressure. When the flame temperature
sensor finds that the flame has reached the required temperature, the boiler starts a new
phase of stabilizing the flame, and then goes into normal work operation.
The boiler works at maximum power until it reaches the set temperature. When the set
temperature is reached, the boiler reduces the working power (modulates its work). If the
default temperature exceeds 5 ° C the boiler will turn off. Once the temperature drops below
the set for 5 ° C, the boiler will start again the ignition phase and return to normal operation.