8. START-UP
Ignition sequence and description of regulation
The basic function of the electronic control unit is to ensure a reliable ignition of the fuel, optimum
combustion conditions and controlled ignition sequence. Depending on the strength and complexity of
the heating system, the parameters are differently read off and controlled. Please note that in some
heating systems the number and value of the parameters may deviate from the above examples but
the basis of the heating system is always the same.
Before startup the boiler, you need to check:
the tank should be filled with pellets
the pellet tank top cover must be closed
the door must be hermetically sealed
the boiler must be connected to 230 V, 50 Hz
Ignition - starting
First, the grate and heat exchanger cleaning phase begins. The display shows CLEANING.
Once the cleaning phase is complete, the pellet dispenser and the burner heaters are started. The
display shows IGNITION.
After the temperature in the burner rises to 65 ° C in relation to the initial, the flame stabilization phase
begins and the display shows STABILIZATION. The flame stabilization phase lasts about 6 minutes.