65
Remove the flame
temperature sensor from the
housing (1), then remove the
four M 8 screws on the heat
exchanger cover.
Raise and remove the heat
exchanger cover upwards.
Leave it to the side, taking
care not to damage the
flame temperature sensor
tube.