NA11 - Manual - 02 - 2009
SETTING AND COMMISSIONING
MMI
Param. setting
enable ON
K1 relay
K2 relay
K3 relay
K4 relay
K5 relay
Min. pulse width
tTR1 150 ms
Mode NO LATCHED
Logic DE-ENERGIZED
Kx relay
Min. pulse width
tTR6 150 ms
Mode NO LATCHED
Logic DE-ENERGIZED
RELAYS
LEDs
Start LED logic
NO LATCHED
Trip LED logic
NO LATCHED
LED 1 logic
NO LATCHED
LED 2 logic
NO LATCHED
LED 3 logic
NO LATCHED
LED 4 logic
NO LATCHED
LED x logic
NO LATCHED
SET
NA10_menuset1.ai
Active Profle
A
PROCEED SET MENU’
BASE
In 5 A
Inp 100 A
IEn 1 A
IEnp 100 A
fn 50 Hz
Reading RELATIVE
Plant
.................
PROFILE A
tCLP> 0.1 s
t>RES 0 s
Type Characteristic:
I>def enable OFF
ICLP>def 2 In
ICLP>inv 2 In
I> Enable OFF
ICLP> Mode OFF
t>def 1 s
I>def 1 In
I>inv enable OFF
t>inv 10 s
I>inv 1 In
I>BLK1 OFF
I>BLK2OUT OFF
I>BLK2IN OFF
I>2ndh-REST OFF
I>BF OFF
I>Curve DEFINITE
I> Element
50/51
I>> Element
I>>> Element
Relays I>
I>TR-K -
I>ST-K -
I>ST-L -
I>TR-L -
LEDs I>
tCLP>> 0.1 s
t>>RES 0 s
Type Characteristic:
I>>def enable OFF
ICLP>>def 2 In
ICLP>>inv 2 In
I>> Enable OFF
ICLP>> Mode OFF
t>>def 1 s
I>>def 1 In
I>>inv enable OFF
t>>inv 5 s
I>>inv 1 In
I>>BLK1 OFF
I>>BLK2OUT OFF
I>>BLK2IN OFF
I>>2ndh-REST OFF
I>>BF OFF
I>disbyI>> OFF
I>>Curve DEFINITE
Relays I>>
I>>TR-K -
I>>ST-K -
I>>ST-L -
I>>TR-L -
LEDs I>>
tCLP>>> 0.1 s
t>>>RES 0 s
I>>>def enable OFF
ICLP>>>def 2 In
I>>> Enable OFF
ICLP>>> Mode OFF
t>>>def 1 s
I>>>def 1 In
I>>>BLK1 OFF
I>>>BLK2OUT OFF
I>>>BLK2IN OFF
I>>>2ndh-REST OFF
I>>>BF OFF
I>disbyI>>> OFF
I>>disbyI>>> OFF
Relays I>>>
I>>>TR-K -
I>>>ST-K -
I>>>ST-L -
I>>>TR-L -
LEDs I>>>
AUTO/RECLOSE 79
79 Enable OFF
MO-RES ON
Phase trip
79-I> OFF
79-I>> OFF
79-I>>> OFF
Earth trip
79-IE> OFF
79-IE>> OFF
79-IE>>> OFF
Relay 79
79-Run-K -
79-AR-K -
79-Fail-K -
LEDs 79
79-Run-L -
79-AR-L -
79-Fail-L -
79 Mode Rapid+Slow
N.DAR 3
MC-td-en OFF
trdt 0.3 s
tsdt 30 s
td1 5 s
td2 5 s
td 5 s
tr 180 s
PROCEED PROFILE A MENU’
SELF-TEST
Self-test relay -
Minor failure
alarm YES
Binary input INx
OFF Delay
tIN1OFF 0 s
IN1 matching None
ON Delay
tIN1ON 0 s
Logic Active-ON
OFF Delay
tIN2OFF 0 s
IN2 matching None
ON Delay
tIN2ON 0 s
Logic Active-ON
BINARY INPUTS
Binary input IN2
Binary input IN1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thytronic NA11 and is the answer not in the manual?

Thytronic NA11 Specifications

General IconGeneral
BrandThytronic
ModelNA11
CategoryRelays
LanguageEnglish

Related product manuals