APPENDIX
8.1 APPENDIX A1 - INPUT-OUTPUT SCHEME
8 APPENDIX
INPUT
For all connections longer than 5m or in environments particularly subject to disturbances due to
power transmission, the use of shielded cables is strictly recommended, with the shield connected
to earth on only one end.
OUTPUT
In case of connections to power relays coils or contactors, it is strictly recommended install protec-
tion devices - like varistors, trapping diodes, etc. - directly on the coils in order to avoid overvoltage
phenomena which can produce disturbances along the cables and/or damage the coils and/or control
relays contacts.
U
E
VOLTAGE
INPUTS
7
8
1
I
L1
I
L2
I
L3
I
E1
2
3
4
5
6
7
8
Local Ethernet
RS485
6
7
B-
A+
X
U
AUX
1
2
C
X
B
A
IN2G
BINARY INPUTS
1
2
3
4
5
6
7
8
9
10
OUTPUT RELAYS
E3
E4
E5
E6
E7
E8
K1
K2
E1
E2
K3
K4
K5
K6
K7
L1
L2
L3
L9
L10
OC1L
K1-1
L4
L5
L6
K1-2
L7
L8
K1-3
K1-4
XMR-T 2 WINDINGS
OPTIONS
5
R_TERM
D1
D2
D3
D4
D5
D6
E9
E10
M1
M2
M3
M9
M10
OC2M
K2-1
M4
M5
M6
K2-2
M7
M8
K2-3
K2-4
IN3H
BINARY INPUTS
1
2
3
4
5
6
7
8
9
10
CURRENT INPUTS SIDE L
BL
OUT
BL
IN
3
4
1
2
+
-
+
-
OPTIONAL
ETHERNET
REMOTE
TX/FX
Z
1
2
3
4
5
6
7
8
CURRENT INPUTS SIDE H
IN1F
BINARY INPUTS
1
2
3
4
5
6
7
8
9
10
FRONT PANEL
I
L1
I
L2
I
L3
I
E2
WARNING
U
E
VOLTAGE
INPUTS
7
8
1
I
L1
I
L2
I
L3
I
E1
2
3
4
5
6
7
8
Local Ethernet
RS485
6
7
B-
A+
X
U
AUX
1
2
C
X
B
A
IN2G
BINARY INPUTS
1
2
3
4
5
6
7
8
9
10
OUTPUT RELAYS
E3
E4
E5
E6
E7
E8
K1
K2
E1
E2
K3
K4
K5
K6
K7
L1
L2
L3
L9
L10
OC1L
K1-1
L4
L5
L6
K1-2
L7
L8
K1-3
K1-4
XMR-T 3 WINDINGS
OPTIONS
5
R_TERM
D1
D2
D3
D4
D5
D6
E9
E10
M1
M2
M3
M9
M10
OC2M
K2-1
M4
M5
M6
K2-2
M7
M8
K2-3
K2-4
IN3H
BINARY INPUTS
1
2
3
4
5
6
7
8
9
10
CURRENT INPUTS SIDE L
BL
OUT
BL
IN
3
4
1
2
+
-
+
-
ETHERNET
REMOTE
TX/FX
Z
1
2
3
4
5
6
7
8
CURRENT INPUTS SIDE H
IN1F
BINARY INPUTS
1
2
3
4
5
6
7
8
9
10
FRONT PANEL
Y
1
2
3
4
5
6
CURRENT INPUTS SIDE T
I
L1
I
L2
I
L3
I
E2
I
L1
I
L2
I
L3
XMR-T EQUIPMENT MANUAL
Ed. 2.9 - 02/2021

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thytronic XMR-T and is the answer not in the manual?

Thytronic XMR-T Specifications

General IconGeneral
BrandThytronic
ModelXMR-T
CategoryProtection Device
LanguageEnglish

Related product manuals