Always grip with the palm of the hand. Do not use the tips of fingers for support.
Always keep the stove as close to the body as possible. This will minimise the
cantilever action.
Use gloves to provide additional grip.
Always use assistance if required.
2. APPLIANCE DATA AND EFFICIENCY
General information.
*When converted using kit 0595261.
The appliance information label is located on a plate at the base of the stove.
Efficiency.
The efficiency of this appliance has been measured as specified in BS EN 613 and
the result is as below:
Model
Efficiency % (Gross)
944 73
944 when converted to LPG. 75
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
Page 6
© Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Gas Natural (G20) Propane (G31) *
Inlet Pressure 20mbar 37mbar
Input - Max. (Gross) 6.85kW (23,372 Btu/h) 6.7kW (22,860 Btu/h)
Input - Min. (Gross) 2.3kW (7,850 Btu/h) 4.0kW (13,650 Btu/h)
Inlet Test Pressure (Cold)
20.0 ± 1.0mbar
(8.0 ± 0.4in w.g.)
37.0 ± 1.0mbar
(14.85 ± 0.4in w.g.)
Gas Connection 8mm pipe 8mm pipe
Burner Injector Cat 82 - 072 Size 130
Pilot
Copreci Ref. O.D.S
21500/212
Copreci Ref. O.D.S
21500/212 Fitted with RBM
180 -02 injector
Ignition
Integral piezo (Mounted on
gas valve)
Integral piezo (Mounted on
gas valve)
Aeration See page 17 Non-adjustable