EasyManua.ls Logo

Titan Logix Corp TD100 - System Specifications

Titan Logix Corp TD100
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TPM 057 Version 1.0, May 31, 2018 Page | 7
OVERVIEW
TD100
nd
Operation
Manual
Figure 9 Air-Weigh Scale
Air-Weigh Load-Maxx
The Air-Weigh Load-Maxx provides over-weight prevention alarms and
shutdowns. Combined with the TD100 and Finch II monitors volume and
weight simultaneously.
Refer to TPM 050 – Air-Weigh Shutdown System Application Note.
3.2 S
YSTEM
S
PECIFICATIONS
Power
8 to
30
VDC @
125
mA max
Accuracy
+/
-
5mm
Resolution
1mm
Repeatability
1mm
Top Deadband
7.
1
inch
Bottom Deadband
4
.5 inch
Materials
SS316L, Hastelloy
®
C276
Process Pressure
14.9 PSI Maximum
Chemical Resistance
Compatible with most substances. Alternate seal
materials available.
Ambient Temperature
-
40F (
-
40C) to 185F (
7
5C)
Process Temperature
-
49F (
-
45C) to 248F (120C)
Dielectric Constant of Measured Liquid
>1.7 (Contact factory to confirm application)
Cable
3 Conductor AWG #14 Max
(AWG #18 recommended)
5 Conductor AWG #14 Max (4-20mA Output Option)
Outputs
SVBus Digital
Optional 4-20mA
Hazardous Area Approvals
Class I, Division 1 Groups B, C, D
Class II, Groups E, F, G
Class III, T5
Class I, Division 2, Groups A, B, C, D T4A
ICES &
FCC Approval
ICES
-
003 Class B, FCC Part 15 Class B

Table of Contents