Important Note regarding Product Liability!
Due to an EC ordinance in eect since 01.01.1990, the manufacturer is liable for his product only if all parts originate from or were
approved by the manufacturer and the devices are assembled and operated correctly. The use of other accessories and spare parts
can partially or completely invalidate the liability.
Correction of Malfunctions
Problem Cause Remedy
The sprayer does
not start.
The sprayer is not plugged in.
•
The device is switched o.
•
The sprayer was turned o while still under
•
pressure.
No voltage is coming from the wall plug.
•
The extension cord is damaged or has too low
•
a capacity.
Device overheated
•
There is a problem with the motor.
•
Plug the sprayer in. ➞
Turn the ON/OFF switch to ON. ➞
Perform pressure relief procedure and set selector ➞
switch back to SPRAY
Properly test the power supply voltage. ➞
Replace the extension cord. ➞
Switch the device o, turn the selector switch to the ➞
PRIME position (vertical), remove the mains plug
and allow device to cool down for min. 30 minutes.
Eliminate the cause of overheating, e.g. covered
ventilation slot.
Please contact your Titan dealer. ➞
The spray device
runs but does not
suck up any paint
when the selector
switch is set to the
PRIME position.
The unit will not prime properly or has lost
•
prime.
The paint bucket is empty or the suction tube
•
is not totally immersed in the paint.
The suction tube is clogged.
•
The suction tube is loose at the inlet valve.
•
The inlet valve is stuck.
•
The inlet valve is worn or damaged.
•
The PRIME/SPRAY valve is plugged
•
Try to prime the unit again. ➞
Rell the bucket or immerse the suction tube in ➞
paint.
Clean the suction tube. ➞
Tighten it securely. ➞
Press the inlet valve pusher. If the problem is not ➞
solved, clean the inlet valve.
Replace ➞
Please contact your Titan dealer. ➞
The sprayer draws
up paint but the
pressure drops
when the gun is
triggered.
The spray nozzle is worn.
•
The inlet lter is clogged.
•
The gun lter is plugged.
•
The paint is too viscous or contaminated.
•
The inlet valve is worn or damaged.
•
Replace the spray nozzle with a new nozzle. ➞
Clean the inlet lter. ➞
Clean or replace the lter. Always keep extra lters on ➞
hand.
Thin or strain the paint. ➞
Replace ➞
The spray gun leaks Internal parts of the gun are worn or dirty.
•
Please contact your Titan dealer. ➞
The nozzle
assembly leaks
The nozzle was assembled incorrectly.
•
A seal is dirty.
•
Check the tip assembly and assemble properly ➞
Clean the seal. ➞
The spray gun will
not spray.
The spray nozzle or the gun lter is plugged.
•
The spray tip is in the reverse position.
•
Clean the spray nozzle or gun lter. ➞
Put the nozzle in the forward position. ➞
The paint pattern is
tailing.
The paint is too viscous or contaminated.
•
The spray nozzle or the gun lter is plugged.
•
The spray nozzle is worn.
•
The inlet lter is clogged.
•
The gun lter is plugged.
•
The inlet valve is worn or damaged.
•
Thin or strain the paint. ➞
Clean the spray nozzle or gun lter. ➞
Replace the spray nozzle with a new nozzle. ➞
Clean the inlet lter. ➞
Clean or replace the lter. Always keep extra lters on ➞
hand.
Replace ➞