EasyManua.ls Logo

Tone TOUCH 03 - 11. TONE WATER SPECIFICATION

Default Icon
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
WATER SPECIFICATION
Required water pressure : 1.5 - 3 bar (20 - 45 psi / 150-300kPa)
IRON: Iron is regulated via the drinking water ordinance with 0.2 mg/L
CHLORINE: Even small amounts of chlorine can lead to a change in taste
CARBONATE HARDNESS: Depending on the coffee; recommendation: individual tasting during
set-up and subsequent fine-tuning of the filter blend, as the KH has the greatest influence.
11. TONE WATER SPECIFICATION
Recommended water parameters for TONE TOUCH 03
VALUE UNITS MINIMUM
above this values a
decarbonation
is necessary
MAXIMUM
Conductivity/T.D.S µS
ppm
120
60
180
100
300
160
Total Hardness ppm
°dH
50
3
100
7
160
9
Total Iron ppm 0,2 mg/l
Free Chlorine ppm
Total Chlorine ppm
pH 6 8
Alkalinity ppm 36 107
Carbonate Hardness °dH 2 4 6
Chloride ppm 0 30
free from chlorine and