3.1 Main features:
Powered by: AC mains power or, 12 v deep cycle lead-acid/gel battery (not included) 30-60 w
solar panel (not included) in conjunction with a 12 v battery as above
5 operating modes
2 different pulse intervals of 1.5 seconds and 2.5 seconds
2 different max output of full and half energy
LED display the energizer working states, power/on/shock
Waterproof and dustproof
Performance Characteristics
output voltage: 7-10 kv
pulse width: 100 us(1/1000 second)
Output energy: 2 / 5 joules
Consumption(Max):
Mars ES 2 : 1.92 watt
Mars ES 5 : 2.4 watt
3.2 Indication and setting
Power light/state (Green)
Power supply is connected from mains power or battery
On: power input is good
1 Hz flash : power is low , energizer will be deactivated
E1 inner error
0.5 Hz flash: E2 inner error
working states(Red) :output energy
On: full power output
Flash : half power output
working states(Red) : interval time
On: 2 second
Flash : 1 second
Change the working state by pushing “UP and “DOWN