Other functions
1. Firmware upgrade
After connecting the M8P to the computer with the USB
cable in the box, the computer will recognize a USB
drive named Toolkit. Download the upgrade file app.upg
from the ToolkitRC website www.toolkitrc.com and
overwrite the files in the drive to upgrade the firmware.
2. Automatically continue charging/ discharging
When a battery is fully charged, connect the next
battery. The device will automatically continue to charge
and discharge, you can start and stop this function in the
settings menu
3. Fan level
When the internal temperature of the device exceeds
45°C, the fan turns at half speed to reduce noise. When
the internal temperature exceeds 53°C, the fan turns on
full-speed to enhance heat dissipation.
4. Manual voltage calibration
With the M8P powered off, press and hold the [roller].
without releasing the roller, connect the power supply,
and the system will enter the manual voltage calibration
mode. Use a voltmeter to measure the actual voltage of
each battery, move the cursor to the corresponding
voltage value, modify the voltage value to match the
voltmeter value. After the calibration is completed,
move the cursor to save, short press once, the buzzer