32
Example
; h1 = 1370; h2 = 1390; h3 = 1362; h4 = 1080
The X axis of instrument is normal because 1.006 is within the range 0.990 to 1.010.
Note
If the calculated result is out of the range, contact your dealer or Topcon.
x(%)= (1390-1080)-(1370-1362) x 100
x(%)= 310 - 8
x 100 =
x(%)= 0.010066 x 100 =
x(%)= 1.006%
30000
30000