6
2.4
PACKING
Every standard product package (cardboard carton) contains:
% N.1 K140 automatic door (complete with motor unit and belt transmission preassembled on the crossbar, side caps,
casing, door stop limit switch, cable raceway, emergency battery,raceway, rubber cable sleeves);
% N.1 package of hardware consisting of , 2 self-tapping screws TC d6x70 and 2 nylon anchor bolts 10x60;
% N.2 Carriage units with relative hardware for fastening to the adapter;
% N.2 Supporting brackets on the crossbar;
% N.1 Adapter for framed door panels;
% N. 2 warning labels for moving wings that have to be sticked on the centre of the moving wings (refer to picture A);
Make sure the parts described above are in the package and that the automation has not undergone any damage in
shipment. If you find anything unusual, do not install the automation and request the service department of the local
retailer or the manufacturer.
The number of some of the parts described above may vary depending on the type of configuration (e.g. number of door
panels).If more parts are necessary, contact the manufacturer.
2.3
TECHNICAL DATA
Tab. 1 lists the technical data that characterize the K140 automation.
POWER SUPPLY
PROTECTION OF ELECTRIC DEVICES
WORKING TEMPERATURE
NUMBER OF DOOR PANELS
230V ~ 50Hz
24V 500mA max
0,32A
70W
Continuous
Adjustable 10 ÷ 80 cm/s
Adjustable 1 ÷ 5 cm/s
Adjustable 0 ÷ 60 s
IP X0
1 PANEL 2 PANELS
K140
MODEL
Tab.
1
PERIPHERAL POWER OUTPUT
POWER ABSORBED
ABSORPTION
OPENING/CLOSING SPEED
OPENING/CLOSING APPROACH SPEED
AUTOMATIC CLOSING TIME
TYPE OF USE
MAINS VOLTAGE FUSE 230V
OPENING/CLOSING ACCELERATION
Adjustable 1 ÷ 12
5 x 20 - T800 delayed
MAXIMUM CAPACITY
SIZE OF OPENING
140 kg
800÷2800 mm
70 + 70 kg
1000÷2800 mm
INSTRUCTIONS FOR INSTALLATION AND USE
EN
K140
-20°C
50°C
warning label
for moving wings
Rif.
A