EasyManua.ls Logo

TorcUP EP500 - Oil Level; Troubleshooting

TorcUP EP500
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TROUBLESHOOTING
PROBLEM CAUSE-SOLUTION
Sporadic Tool Action: Air in the hydraulic system. Bleed the hydraulic circuit.
Check reservoir oil level.
Motor Will Not Start: Be sure power cord is not damaged.
Check for tripped circuit breaker; be sure breaker is of
adequate size.
Have motor checked for proper operation.
Have qualied electrician inspect for loose or faulty wiring or
switch.
.
Noisy Operation: Air in system.
Be sure the oil reservoir is lled to normal level.
Check all points where air might leak into system.
Clogged or blocked intake screen.
Pump Oil is Over Heating: Inspect for high pressure leakage at the pump (leaking at
plug or relief valve).
Oil level is low. Fill reservoir to normal level, or retrot the
pump with larger reservoir or heat exchanger.
Pump Runs But Will Not Pump Oil: Pump is not primed. Run pump a few minutes tipping from
side to side.
Inspect to make sure that external adjustable relief valve is
set properly.
Defective control valve, take to nearest TorcUP Authorized
Service Center for repair.
Incorrect motor rotation, take to nearest TorcUP Authorized
Service Center for repair.
Check to make sure the intake screen is not clogged. Clean
if needed.
Check oil reservoir is low. Fill as needed.
Oil viscosity is too high. Replace with TorcUP oil.
11/37