Groundsmaster 4500--D/4700--D Page 5 -- 33 Electrical System
Service and Repairs
NOTE: For more component repair information, see
the Kubota Workshop Manual, Diesel Engine,
V2403--M--T--E3BattheendofChapter3 -- KubotaDie-
sel Engines.
Battery Storage
If the machine will be stored for more than 30 days:
1. Remove the battery and charge it fully (see Battery
Service in this section).
2. Either store battery on a shelf or on the machine.
3. Leavec ablesdisconnectedifthebatteryisstoredon
the machine.
4. Storebatteryinacoolatmospheretoavoidquickde-
terioration of the battery charge.
5. Tohelppreventthebatteryfrom freezing,makesure
it is fully charged (see Battery Service in this section).
Battery Care
1. Battery electrolyte level must be properly main-
tained. The top of the battery must be kept clean. lf the
machine is s tored in a location where temperatures are
extremely high, the battery will discharge more rapidly
thanifthemachineisstoredinalocationwheretemper-
atures are cool.
WARNING
Wear safety goggles and rubber gloves when
working with electrolyte. Charge battery in a
well ventilated place so gasses produced while
charging can dissipate. Since the gases are ex-
plosive,keepopen flames andelectricalsparks
away from the battery; do not smoke. Nausea
mayresultifthegasesareinhaled.Unplugchar-
ger from electrical outlet before connecting or
disconnecting charger leads to or from battery
posts.
IMPORTANT: Do not remove fill caps while clean-
ing.
2. Check battery condition weekly or after every 50
hours of operation. Keep terminals and entire battery
casecleanbecauseadirtybatterywilldischargeslowly.
A. Clean batterybywashingentirecasewithasolu-
tionofbakingsodaandwater.Rinsewithclearwater.
B. Coatbatterypostsandcableconnectorswithbat-
tery terminal protector (see Special Tools in this
chapter) or petroleum jelly to prevent corrosion.
3. Battery cables must be tight on terminals to provide
good electrical contact.
Connecting cables to the wrong post could re-
sultinpersonalinjuryand/ordamageto theelec-
trical system.
WARNING
4. If corrosion occurs at terminals, disconnect cables.
Always disconnect negative (--) cable first. Clean
clamps and terminals separately. Reconnect cables
withpositive(+)cablefirst.Coatbatterypostsandcable
connectors with battery terminal protector (see Special
Toolsin thischapter)orpetroleum jellytopreventcorro-
sion.
5. Checkelectrolytelevelevery25operatinghoursand
every 30 days if machine is in storage.
6. Maintaincelllevelwithdistilledordemineralizedwa-
ter. Do not fill cells above the fill line.