Groundsmaster 4500--D/4700--D Hydraulic SystemPage 4 -- 25
Mow Circuit
Hydraulic flow for the mow circuit is supplied by two (2)
sectionsofthegearpump(P1andP2).Gearpumpsec-
tion P1 supplies hydraulic flow to decks 5, 3 and 2 (also
deck7ontheGM4700--D),whilegearpumpsectionP2
suppliesdecks1and4(alsodeck6ontheGM4700--D).
A single deck control manifold is used to control flow
from the two (2) pump sections. The manifold includes
cartridge valves for control of each of the two (2) pump
circuits. Each manifold circuit is equipped with a sole-
noid controlled, proportional relief v alve (PRV1/PRV2),
a logic cartridge (LC1/LC2) and a brake relief cartridge
(RV8/RV9).TheGroundsmaster4700--Ddeckmanifold
includes additional cartridges to control hydraulic flow
for decks 6 and 7: an additional logic cartridge
(LC3/LC4),asolenoidvalve(SV1/SV2)andanaddition-
al brake relief cartridge (RV10/RV11).
PTO Disengaged
WhenthePTOswitchisOFF(orifthedecksareraised),
the manifold solenoid valves (PRV1 and PRV2) are not
energized, allowing hydraulic flow to bypass the deck
motors through the manifold. Return oil from the man-
ifolds is directed to the oil cooler and oil filter.
PTO Engaged
When the PTO switch is turned ON with the decks low-
ered, the solenoid valves (PRV1 and PRV2) are ener-
gized with outputs from the TEC--5002 controller. The
energized valves shift to direct pump flow toward the
deck motors. As circuit pressure to the deck motors in-
creases, the brake relief cartridge (RV) opens which al-
lows an oil flow through the manifold orifice positioned
beforethelogiccartridge(LC).This flowcreatesapres-
sureincreaseatthelogicc artridgethatwillshiftthelogic
cartridge and allow oil return from the deck motors.
On the Groundsmaster 4700--D (Fig. 19), if deck 6 or
deck 7 is lowered and the PTO switch is ON, the deck
control manifold solenoid valve (SV1/SV2) will be ener-
gized by the TEC--5001 controller. This energized sole-
noid valve allows oil flow to the appropriate deck motor
as described above.
Maximum mow circuit pressure is limited at each deck
manifold circuit by the proportional relief valve
(PRV1/PRV2). The deck relief valve pressure is 3500
PSI(241bar).Mowcircuitpressurecanbemeasuredat
port G1 or G3 of the deck control manifold.
Thebrakereliefandlogiccartridgescontrolthestopping
rate of the blades when the solenoid v alves are de--en-
ergized as the PTOswitch is turned OFF or if the decks
are raised (see Cutting Deck Blade Braking in this sec-
tion).
Figure 18
#4 Deck #1 Deck #5 Deck
#7 Deck
(GM4700)
#6 Deck
(GM4700)
#3
Deck
#2
Deck
CUTTING DECK LOCATIONS
Figure 19
DECK CONTROL MANIFOLD
FROM
(Groundsmaster 4700--D)
FROM
TO DECKS
FROM
1&4
DECKS
1&4
TO DECKS
2, 3 & 5
TO DECK
6
FROM
DECK 6
FROM
DECKS
2, 3 & 5
TO DECK
7
FROM
DECK 7
PUMP P1
PUMP P2
TO OIL
COOLER
PTO SWITCH ON AND
#7 (RH) DECK RAISED
Hydraulic
System