4. Slo wly pour distilled w ater into eac h batter y
cell until the electrolyte lev el is up to the Upper
line ( Figure 32 ) on the batter y case .
Important: Do not o v erfill the batter y
because electr ol yte (sulfuric acid) can
cause sev er e cor r osion and dama ge to the
chassis.
5. W ait fiv e to ten min utes after filling the batter y
cells . Add distilled w ater , if necessar y , until
the electrolyte lev el is up to the Upper line
( Figure 32 ) on the batter y case .
6. R einstall the batter y v ent caps .
Charging the Battery
Important: Al w ays k eep the batter y
full y charged (1.260 specific g ra vity). T his
is especiall y impor tant to pr ev ent batter y
dama ge when the temperatur e is belo w 32°F
(0°C).
1. R emo v e the batter y from the c hassis; refer to
R emo ving the Batter y .
2. Chec k the electrolyte lev el; refer to Chec king
the Electrolyte Lev el.
3. Mak e sure that the v ent caps are installed in
the batter y . Charg e the batter y for 1 hour at 25
to 30 amps or 6 hours at 4-6 amps . Do not
o v erc harg e the batter y .
4. W hen the batter y is fully c harg ed, unplug
the c harg er from the electrical outlet, then
disconnect the c harg er leads from the batter y
posts ( Figure 33 ).
Figure 33
1. Positive battery post
3. Red (+) charger lead
2. Negative battery post
4. Black (-) charger lead
5. Install the batter y in the tractor and connect the
batter y cables; refer to Installing the Batter y .
Note: Do not r un the tractor with the batter y
disconnected, electrical damag e ma y occur .
Servicing the Fuses
Ser vice Inter v al/Specification
T he electrical system is protected b y fuses . It
requires no maintenance; ho w ev er , if a fuse blo ws ,
c hec k the component/circuit for a malfunction
or shor t.
Fuse:
Main F1–30 amp , blade-type
Charg e Circuit F2–25 amp , blade-type
Optional Headlight Kit–10 amp , blade type
1. Raise the seat to g ain access to the fuse holder
( Figure 34 ).
2. T o re place a fuse , pull out on the fuse to
remo v e it ( Figure 34 ).
Figure 34
1. Main–30 amp
3. For optional Headlight
Kit–10 amp
2. Charge circuit–25 amp
Drive System
Maintenance
Checking the Tire Pressure
Maintain the air pressure in the front and rear
tires as specified. Unev en tire pressure can cause
29