EasyManua.ls Logo

Toro 74920 TITAN ZX4820 - Using the Rollover Protection System (ROPS)

Toro 74920 TITAN ZX4820
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Followthemanufacturer'srecommendationsforwheel
weightsorcounterweightstoimprovestability.
Useextremecarewithgrasscatchersorotherattachments.
Thesecanchangethestabilityofthemachineandcause
lossofcontrol.
UsingtheRolloverProtectionSystem
(ROPS)
Keeptherollbarintheraisedandlockedpositionand
usetheseatbeltwhenoperatingthemachine.
Becertainthattheseatbeltcanbereleasedquicklyin
theeventofanemergency.
Beawarethereisnorolloverprotectionwhentheroll
barisdown.
ChecktheareatobemowedandneverfoldtheROPSin
areaswherethereareslopes,dropoffsorwater.
Lowertherollbaronlywhenabsolutelynecessary.Donot
weartheseatbeltwiththerollbarfoldeddown.
Checkcarefullyforoverheadclearances(i.e.branches,
doorways,electricalwires)beforedrivingunderany
objectsanddonotcontactthem.
Model74920
SoundPower
Thisunithasaguaranteedsoundpowerlevelof105dBA,
whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinISO11094.
SoundPressure
Thisunithasasoundpressurelevelattheoperator’searof93
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinEN836.
Hand-ArmVibration
Measuredvibrationlevelforlefthand=2.4m/s2
Measuredvibrationlevelforrighthand=2.6m/s2
UncertaintyValue(K)=1.3m/s2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinEN836.
WholeBodyVibration
Measuredvibrationlevel=0.63m/s2
UncertaintyValue(K)=0.31m/s2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinEN836(Riding&Stand-Ons).
Model74924
SoundPower
Thisunithasaguaranteedsoundpowerlevelof105dBA,
whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinISO11094.
SoundPressure
Thisunithasasoundpressurelevelattheoperator’searof93
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinEN836.
Hand-ArmVibration
Measuredvibrationlevelforlefthand=3.1m/s2
Measuredvibrationlevelforrighthand=2.7m/s2
UncertaintyValue(K)=1.5m/s2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinEN836.
WholeBodyVibration
Measuredvibrationlevel=0.71m/s2
UncertaintyValue(K)=0.35m/s2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinEN836(Riding&Stand-Ons).