The Special Functions dial position provides optional
control features specifically for pump system operation.
Pump/Master Valve control circuit operation is active
(On) with two seconds of delay time (turns on two sec-
onds before the first zone begins watering) but can be
turned Off for each watering program as needed.
The pump delay time can be adjusted from 1 to 60
seconds.
Turn the control dial to the special functions
position.
Check the programs switch setting. If necessary,
reposition the switch to select the desired program.
3. The display will show P On (Pump On) and will
begin flashing.
To turn the pump circuit Off for this program, press
the –/off button; P OFF will be displayed.
Press the next button to display the pump delay
time. Pd 02 will be displayed. (A two-second pump
delay is set by default for each program).
Press the +/on or –/off button until the desired time
is shown (2 to 60 seconds).
Pump Control
29
1
6
3
5
2
4
6
5