Figure67
1.Cam
2.Nut
8.Adjustthecamuntilitalignswiththeleft
motion-controlleverandtightenthenutforthecam.
Note:Movingthecamclockwise(inthevertical
position)lowersthehandle;movingthecam
counterclockwise(intheverticalposition)raisesthe
handle.
Important:Ensurethattheatportionofthe
camdoesnotgoaboveaverticalposition(rightor
left);otherwiseyoumaydamagetheswitch.
9.Repeatsteps3through8fortheleftmotion-control
lever.
HydraulicSystem
Maintenance
ServicingtheHydraulic
System
HydraulicFluidType:Toro
®
HYPR-OIL
™
500hydraulic
oil
HydraulicSystemFluidCapacity:4.7L(5USqt)
Important:Usetheuidspecied.Otheruidscould
damagethesystem.
CheckingtheHydraulicFluid
ServiceInterval:Aftertherst8hours
Every500hours
Note:Checkthehydraulicuidlevelwhentheuidiscold.
1.Positionthemachineonalevelsurface.
2.Disengagethepowertakeoff(PTO)andshutoffthe
engine.
3.Waitforallmovingpartstostopandsettheparking
brakebeforeleavingtheoperatingposition.
4.Cleantheareaaroundthecapandthellerneckofthe
hydraulictank(Figure68).
Figure68
1.Hydraulic-tankcap2.Filllevel
5.Removethecapfromthellerneck(Figure68).
Note:Lookinsidetochecktheuidlevelinthe
reservoir.
6.Adduidtothereservoiruntilitreachesthelllevel.
7.Installthecaponthellerneck.