17
835S Series Performance Chart—(U.S.)
Base
Pressure
Nozzle Set 30
(White)
Nozzle Set 31
(Yellow)
Nozzle Set 32
(Blue)
Nozzle Set 33
(Brown)
Nozzle Set 34
(Orange)
Nozzle Set 35
(Green)
Nozzle Set 36
(Gray)
Nozzle Set 37
(Black)
102-2208 102-4587 102-4588 102-4589 102-0728 102-0729 102-0730 102-4261
Blue Gray Blue Gray Red Gray Orange Gray Orange Gray Blue Gray Blue Gray Orange Gray
102-2925 102-2910 102-2925 102-2910 102-2928 102-2910 102-2926 102-2910 102-2926 102-2910 102-2925 102-2910 102-2925 102-2910 102-2926 102-2910
psi Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM
50 42 7.1 52 13.7 61 17.1 64 20.2 69 27.4
65 45 8.7 54 15.5 63 20.5 66 22.9 74 30.0 76 32.4 80 34.0
80 46 9.6 57 17.0 67 22.6 70 25.3 77 33.2 79 35.8 84 37.5 86 40.8
100 48 11.2 59 18.9 72 25.2 74 28.2 80 37.0 84 39.9 88 42.5 92 45.3
Stator 102-6929 Blue 102-1939 Yellow 102-1940 White
Conversions 835S-3134 835S-3537
Not recommended at these pressures. Radius shown in feet.
Toro recommends the use of a 1
1
⁄4" swing joint at flows over 25-GPM (95-LPM). Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1.
Actual site conditions must be considered when selecting the appropriate nozzle.
All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 psi.
855S Series Performance Chart—(U.S.)
Base
Pressure
Nozzle Set 51
(Yellow)
Nozzle Set 52
(Blue)
Nozzle Set 53
(Brown)
Nozzle Set 54
(Orange)
Nozzle Set 55
(Green)
Nozzle Set 56
(Gray)
Nozzle Set 57
(Black)
Nozzle Set 58
(Red)
Nozzle Set 59
(Beige)
102-4587 102-4588 102-4589
102-0728
102-0729 102-0730 102-4261 102-4260 102-4259
Blue Gray Red Gray
Orange
Gray
Orange
Gray Blue Gray Blue Gray
Orange
Gray Blue Gray Blue Gray
102-2925 102-2910 102-2928 102-2910 102-2926 102-2910 102-2926 102-2910 102-2925 102-2910 102-2925 102-2910 102-2926 102-2910 102-2925 102-2910 102-2925 102-2910
psi
Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM Radius GPM
50 52 13.9 62 17.4 66 20.7 69 28.6
65 54 15.7 64 20.8 68 23.4 74 31.2 76 33.8 81 35.7
80 57 17.2 68 22.9 72 25.8 77 34.4 79 37.2 85 39.4 89 43.6 92 47.5 96 57.0
100 59 19.1 73 25.5 76 28.7 80 38.2 84 41.3 89 43.7 94 48.5 95 51.1 100 61.1
Stator 102-1939 Yellow 102-1940 White
102-1941
Conver.
855S-5154 855S-5558 855S-59
Not recommended at these pressures. Radius shown in feet.
Toro recommends the use of a 1
1
⁄4" swing joint at flows over 25-GPM (95-LPM). Sprinkler radius data collected in Toro’s zero wind test facility per ASAE standard S398.1.
Actual site conditions must be considered when selecting the appropriate nozzle.
All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 psi.
Specifying Information—835S & 855S
8X5S-XX-XXXXX
Body
Inlet
Arc
Body
Threads
Valve Type Nozzle
Pressure
Regulation*
Optional
8X5S X X X X X X X
3—1"
5—1
1
2"
5— Part-circle and
Full-circle
in one
0—NPT
4—ACME
5—BSP
1— Normally
Open Hydraulic
2— Check-O-Matic
6—Electric
835S:
30 31 32 33 34 35 36 37
855S:
51 52 53 54 55 56 57 58 59
6—65 psi
8—80 psi
E— Effluent model
DL— Decoder model
N— Nickel plated model
Example: When specifying an 835S Series Sprinkler with NPT threads, #34 nozzle, an electric valve and pressure regulation at 65 psi you would specify: 835S–06–346
* Electric models only. All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 psi.
Note: Not all models available. Nickel-plated, corrosion-resistant models are available upon request.
835S Series Performance Chart—(Metric)
Base Pressure
Nozzle Set 30
(White)
Nozzle Set 31
(Yellow)
Nozzle Set 32
(Blue)
Nozzle Set 33
(Brown)
Nozzle Set 34
(Orange)
Nozzle Set 35
(Green)
Nozzle Set 36
(Gray)
Nozzle Set 37
(Black)
102-2208 102-4587 102-4588 102-4589 102-0728 102-0729 102-0730 102-4261
Blue Gray Blue Gray Red Gray Orange Gray Orange Gray Blue Gray Blue Gray Orange Gray
102-2925 102-2910 102-2925 102-2910 102-2928 102-2910 102-2926 102-2910 102-2926 102-2910 102-2925 102-2910 102-2925 102-2910 102-2926 102-2910
Bar kPa kg/cm
2
Radius LPM Radius LPM Radius LPM Radius LPM Radius LPM Radius LPM Radius LPM Radius LPM
3,4 340 3,47 12,8 26,9 15,9 51,9 18,6 64,7 19,5 76,5 21,0 103,7
4,5 450 4,59 13,7 32,9 16,5 58,7 19,2 77,6 20,1 86,7 22,6 113,6 23,2 122,6 24,4 128,7
5,5 550 5,61 14,0 36,3 17,4 64,3 20,4 85,5 21,4 95,8 23,5 125,7 24,1 135,5 25,6 141,9 26,2 154,4
6,9 690 7,04 14,6 42,4 18,0 71,5 22,0 95,4 22,6 106,7 24,4 140,0 25,6 151,0 26,8 160,9 28,1 171,5
Stator 102-6929 Blue 102-1939 Yellow 102-1940 White
Conversions 835S-3134 835S-3537
Not recommended at these pressures, Radius shown in meters, Toro recommends the use of a 11⁄4" (30mm) swing joint at flows over 25-GPM (95-LPM),
Sprinkler radius of throw per ASAE standard S398,1,
855S Series Performance Chart—(Metric)
Base
Pressure
Nozzle Set 51
(Yellow)
Nozzle Set 52
(Blue)
Nozzle Set 53
(Brown)
Nozzle Set 54
(Orange)
Nozzle Set 55
(Green)
Nozzle Set 56
(Gray)
Nozzle Set 57
(Black)
Nozzle Set 58
(Red)
Nozzle Set 59
(Beige)
102-4587 102-4588 102-4589
102-0728
102-0729 102-0730 102-4261 102-4260 102-4259
Blue Gray Red Gray
Orange
Gray
Orange
Gray Blue Gray Blue Gray
Orange
Gray Blue Gray Blue Gray
102-2925 102-2910 102-2928 102-2910 102-2926 102-2910 102-2926 102-2910 102-2925 102-2910 102-2925 102-2910 102-2926 102-2910 102-2925 102-2910 102-2925 102-2910
Bar kPa kg/cm
2
Radius LPM Radius LPM Radius LPM Radius LPM Radius LPM Radius LPM Radius LPM Radius LPM Radius LPM
3,4 340 3,47 15,9 52,6 18,9 65,9 20,1 78,3 21,0 108,3
4,5 450 4,59 16,5 59,4 19,5 78,3 20,7 88,6 22,6 113,1 23,2 127,9 24,7 135,1
5,5 550 5,61 17,4 65,1 20,7 86,7 22,0 97,7 23,5 130,2 24,1 140,8 25,9 149,1 27,1 165,0 28,1 179,8 29,3 215,7
6,9 690 7,04 18,0 72,3 22,3 96,5 23,2 108,6 24,4 144,6 25,6 156,3 27,1 165,4 28,7 183,6 29,0 194,9 30,5 231,3
Stator 102-1939 Yellow 102-1940 White
102-1941
Conversions
855S-5154 855S-5558 855S-59
Not recommended at these pressures, Radius shown in meters, Toro recommends the use of a 11⁄4" (30mm) swing joint at flows over 25‑GPM (95‑LPM), Sprinkler radius of throw per ASAE standard S398,1,

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toro Lynx and is the answer not in the manual?

Toro Lynx Specifications

General IconGeneral
ManufacturerToro
Flow ManagementYes
Output Voltage24 VAC
CommunicationWireless
Remote ControlYes
ReportingYes

Related product manuals