79
PERFORMANCE VERIFICATION
Refer to the preceding information in this manual for complete and detailed instructions.
Follow all Safety Instructions.
Gallons Per Acre:
Determine Desired Application Rate From
Manufacturers Labeling ________ G.P.A.
Determine a Vehicle Application Speed _____
M.P.H.
Verify Nozzle Spacing is 20.
Determine Gallons Per Minute
G.P.M.
(See Nozzle Chart on Page 57 & 58) and Use
The Following Formula to verify.
G.P.A. X M.P.H. X 20
5940
x x 20 = = G.P.M.
5940 5940
Select Nozzle Size (See Nozzle Chart on
Page 57 & 58)
based on G.P.M.
Determine Application Pressure
psi
(See Nozzle Chart on Page 57 & 58).
Gallons Per 1,000 sq. ft.:
Determine Desired Application Rate From
Manufacturers Labeling ________ G.P. 1,000 sq. ft.
Determine a Vehicle Application Speed _____
M.P.H.
Verify Nozzle Spacing is 20
Determine Gallons Per Minute
G.P.M. ( See
Nozzle Chart on Page 59 & 60) and Use The
Following Formula to verify
G.P. 1,000 sq. ft. X M.P.H. X 20
136
x x 20 = = G.P.M.
136 136
Select Nozzle Size (See Nozzle Chart on
Page 59 & 60
based on G.P.M.
Determine Application Pressure
psi
(See Nozzle Chart on Page 59 & 60)
OPTIONAL RATE CHECK
(WATER ONLY)
1. Verify G.P.A. application rate via 1/128th Acre Method.
2. Mark off a test course in a flat area at 204 feet.
3. Drive the Sprayer at a constant speed with a ½ full tank of water in selected range and record the
time it takes to drive 204 feet.
seconds. NOTE: Drive at full engine speed in that range
selection regardless of any target operating speed.
4. Park Vehicle. SET PARKING BRAKE.
5. Turn on pump and all booms and use Neutral Engine Speed Control to lock in full engine speed.
6. Hold a graduated cylinder under the far left nozzle on the left boom. Collect the output for the same
amount of time that it took to travel 204 ft.
7. Each ounce of fluid collected equals a 1 gallon per acre application rate.