TestingtheKeySwitch(continued)
4.Useamultimeter(ohmssetting)andtheprecedingtabletodetermine
whethercontinuityexistsbetweenthevariousterminalsforeachswitch
position.
5.Replacetheswitchifnecessary.
6.Iftheswitchtestscorrectlyandacircuitproblemstillexists,checkthewire
harnesses;refertoAppendixA(pageA–1).
7.Installtheswitchandconnectthewireharnessaftertesting.
8.Connectthebatterynegative(-)cableatthebattery.
ElectricalSystem:TestingtheElectricalComponents