Cutting Unit Operating Problems
Problem Possible Causes
Engine Continues to run (but should not) when the
cutting unit switch is ON with no operator in the seat.
Backlap switch is in the backlap position.
Backlap switch is faulty or out of adjustment.
Wiring to the run/mow/backlap circuits (see Wiring
Schematics) components is loose, corroded, or
damaged.
Seat switch is faulty, out of adjustment, or short
circuited.
Cutting units run (but should not) when raised. Cutting unit interlock switch is faulty.
However, they shut off with the cutting unit switch
Cutting units shut off when raised. However, they do Cutting unit switch is faulty or short circuited.
not shut off with the cutting unit switch.
Cutting units do not engage. Wiring to run/mow/backlap circuits (see Wiring
Schematics) components is loose, corroded, or
damaged.
ACC fuse (10 amp) is open.
Fuse block is faulty.
Cutting units are not lowered.
Cutting unit switch is faulty.
Cutting unit interlock switch is faulty.
Cutting solenoid valve is faulty.