Reelmaster 3550--DPage 5 -- 26Electrical System
Fusible Link Harness
The Reelmaster 3550--D uses three (3) fusible links for
circuit protection. These fusible links are located in a
harness that connects the starter B+ terminal to the
main wire harness. If any of these links should fail, cur-
rent to the protected circuit will cease. Refer to electrical
schematic in Chapter 8 -- Foldout Drawings for addition-
al fusible link information.
Testing
Make sure that ignition switch is OFF and disconnect
negative battery cable from battery terminal. Then dis-
connect positive cable from battery (see Battery Service
in the Service and Repairs section of this chapter). Lo-
cate and unplug fusible link connector (P1) from ma-
chinewireharness.Useamultimetertomakesurethat
continuity exists between each terminal pin in connector
P1 and connector J1 at the starter (Fig. 32). If any of the
fusible links are o pen, replace the fusible link harness.
After testing is complete, make sure that fusible link har-
ness connectors are securely attached to starter and
machine wire harness. Connect positive battery cable to
battery terminal first and then connect negative cable to
battery.