Reelmaster 3550−D/3555−D/3575−DHydraulic System Page 4 − 116
Lift Control Manifold Service (Reelmaster 3550−D)
1. Lift control manifold
2. Dust cover
3. SAE #4 plug with O−ring (2)
4. Relief valve (RV1)
5. Solenoid valve (S1)
6. Solenoid valve (S2)
7. Solenoid valve (S3 and S4)
8. Solenoid coil (4)
9. Coil spacer (2)
10. Orifice (0.035) (port C7)
11. Orifice (0.055) (port C8)
12. Orifice (0.040) (ports C1, C3 & C5)
13. Orifice (0.046) (ports C2, C4 & C6)
14. Straight fitting (6)
15. Straight fitting (2)
16. Coil nut (3)
17. Tall coil nut
18. Straight fitting (2)
19. Diagnostic fitting
Figure 75
FRONT
VIEW FROM
ABOVE
FRONT
VIEW FROM
ABOVE
3
6
8
9
10
11
7
15
16
18
19
2
4
8
9
13
5
7
12
14
16
8
16
3
8
12
13
17
1
1
60 in−lb
(6.7 N−m)
20 ft−lb
(27 N−m)
25 ft−lb
(33 N−m)
20 ft−lb
(27 N−m)
20 ft−lb
(27 N−m)
20 ft−lb
(27 N−m)
20 ft−lb
(27 N−m)
60 in−lb
(6.7 N−m)
20 ft−lb
(27 N−m)
20 ft−lb
(27 N−m)