EasyManua.ls Logo

Toro Reelmaster 3555-D - Bedbar Assembly

Toro Reelmaster 3555-D
338 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reelmaster 3550--D/3555--D/3575--D
DPA Cutting Units
Page 7 -- 18
Bedbar Assembly
Figure 27
FRONT
RIGHT
18” Cutting Unit Components Shown
Serial No. 315000001 & Up
1. Bedbar assembly
2. Lock nut (2 used)
3. Compression spring (2 used)
4. Washer (2 used)
5. Plastic washer (4 used)
6. Rubber bushing (2 used)
7. Flange bushing (2 used)
8. Metal washer (2 used)
9. Bedbar pivot bolt (2 used)
10. Lock nut (2 used)
Antiseize
Lubricant
7
8
9
10
6
5
5
27 to 33 ft--lb
(37to44N--m)
4
3
2
1
Bedbar Removal (Fig. 27)
1. Position machine on a clean and level surface, lower
cutting units, stop engine, engage parking brake and re-
move key from the ignition switch.
2. Remove the cutting unit from the machine. Use the
cutting unit kickstand to support the cutting unit (see
Special Tools).
3. Loosen the lock nuts on the end of each bedbar ad-
juster assembly until washers are loose.
4. Loosen the lock nuts on each bedbar pivot bolt.
5. Remove two (2) bedbar pivot b olts, two (2) metal
washers and four (4) plastic washers from the cutting
unit side plates.
DPA C utting
Units

Table of Contents