Loading...
WARNING:
BEFORE
SERVICING
THIS
CHASSIS,
READ
THE
“X-RAY
RADIATION
PRECAUTION’,
“SAFETY
PRECAUTION”
AND
“PRODUCT
SAFETY
NOTICE”
ON
PAGE
2
OF
THIS
MANUAL.
INSTALLATION
AND
SERVICE
ADJUSTMENTS
GENERAL
INFORMATIONS
All
adjustments
are
thoroughly
checked
and
corrected
when
the
receiver
leaves
the
factory.
Therefore
the
receiver
should
operate
normally
and
produce
proper
colour
and
B/W
pictures
upon
installation.
However,
several
minor
adjustments
may
be
required
depending
on
the
particular
location
in
which
the
receiver
is
operated.
This
receiver
is
shipped
completely
in
cardboard
carton.
Carefully
draw
out
the
receiver
from
the
carton
and
remove
all
packing
materials.
Plug
the
power
cord
into
a
convenient
220
volts
50
Hz
AC
two
pin
power
outlet.
Turn
the
receiver
ON.
Check
and
adjust
all
the
customer
controls
such
as
BRIGHTNESS,
CONTRAST
and
COLOUR
Controls
to
obtain
natural
colour
or
B/W
picture.
AUTOMATIC
DEGAUSSING
A
degaussing
coil
is
mounted
around
the
picture
tube
so
that
external
degaussing
after
moving
the
receiver
is
normally
unnecessary,
providing
the
receiver
is
properly
degaussed
upon
installation.
The
degaussing
coil
operates
for
about
1
second
after
the
power
to
the
receiver
is
switched
ON.
If
the
set
is
moved
or
faced
in
a
different
direction,
the
power
switch
must
be
switched
off
at
least
30
minutes
in
order
that
the
automatic
degaussing
circuit
operates
properly.
Should
the
chassis
or
parts
of
the
cabinet
become
magnetized
to
cause
poor
colour
purity,
use
an
external
degaussing
coil.
Slowly
move
the
degaussing
coil
around
the
faceplate
of
the
picture
tube,
the
sides
and
front
of
the
receiver
and
slowly
withdraw
the
coil
to
a
distance
of
about
2
m
before
disconnecting
it
from
AC
source.
HIGH
VOLTAGE
CHECK
CAUTION:
There
is
no
HIGH
VOLTAGE
ADJUST-
oe
on
this
chassis.
.
Connect
an
accurate
high
voltage
meter
to
the
second
anode
of
the
picture
tube.
2.
Turn
on
the
receiver.
Set
the
BRIGHTNESS
and
CONTRAST
Controls
to
minimum
(zero
beam
current).
3.
High
voltage
will
be
measured
below
32.0
kV.
4.
Rotate
the
BRIGHTNESS
Control
to
both
extremes
to
be
sure
the
high
voltage
does
not
exceed
the
limit
of
32.0
kV
under
any
conditions.
FOCUS
ADJUSTMENT
Adjust
FOCUS
Control
on
FLYBACK
TRANS.
(1461)
for
well
defined
scanning
lines
in
the
centre
area
on
the
screen.,

Related product manuals