Do you have a question about the Toshiba Carrier MMK-AP0183H2UL and is the answer not in the manual?
Brand | Toshiba |
---|---|
Model | Carrier MMK-AP0183H2UL |
Category | Air Conditioner |
Language | English |
Explains the meaning of warning indications like DANGER, WARNING, CAUTION.
Explains the meaning of illustrated marks like prohibition, mandatory items, and cautions.
Confirms that warning labels are indicated on specified positions on the unit.
Lists technical specifications for the 4-Way Cassette Type indoor units.
Lists technical specifications for the Compact 4-Way Cassette Type indoor units.
Lists technical specifications for the Ceiling Type indoor units.
Lists technical specifications for the High Wall Type indoor units.
Provides external view diagrams and dimensions for 4-Way Cassette Type units.
External view diagrams and dimensions for Compact 4-Way Cassette Type units.
External view diagrams and dimensions for Ceiling Type units.
External view diagrams and dimensions for High Wall Type units.
Wiring diagram for 4-Way Cassette Type indoor units.
Wiring diagram for Compact 4-Way Cassette Type indoor units.
Wiring diagram for Ceiling Type indoor units.
Wiring diagram for High Wall Type indoor units.
Lists parts ratings for 4-Way Cassette Type indoor units.
Lists parts ratings for Compact 4-Way Cassette Type indoor units.
Lists parts ratings for Ceiling Type indoor units.
Lists parts ratings for High Wall Type indoor units.
Outlines control functions for 4-Way Cassette, Compact 4-Way, and Ceiling Type units.
Outlines control functions specific to High Wall Type units.
Illustrates controller block diagrams for various remote controller configurations.
Provides details on specific indoor P.C. boards (MCC-1570, MCC-1402) and their types.
Covers test run procedures, fan control, prevention, and other operational functions.
Details DN code settings, P.C. board replacement, addressing, error clearing, and monitoring.
Explains PC board LEDs and wireless controller A-B selection.
Provides an overview of troubleshooting, applicable models, tools, and general checks.
Lists and explains check codes detected by various devices for fault identification.
Guides troubleshooting using information displayed on the remote controller and error history.
Details check codes displayed on remote controllers and outdoor unit 7-segment displays.
Provides resistance characteristics for indoor unit temperature sensors.
Details the detachment and attachment procedures for parts of 4-Way Cassette Type units.
Details detachment and attachment procedures for parts of Compact 4-Way Cassette Type units.
Details detachment and attachment procedures for parts of Ceiling Type units.
Details detachment and attachment procedures for parts of High Wall Type units.
Procedures for replacing P.C. boards in 4-Way, Compact 4-Way, and Ceiling Type units.
Reads setting data from the P.C. board via wired remote controller.
Details the process for replacing the indoor P.C. board assembly.
Procedures for replacing P.C. boards in High Wall Type units.
Writes setting data into the EEPROM of the service P.C. board.
Exploded views and parts list for 4-Way Cassette Type units.
Exploded views and parts list for Compact 4-way Cassette Type units.
Exploded views and parts list for Ceiling Type units.
Exploded views and parts list for High Wall Type units.
Details concentration limits and requirements for refrigerant leakage in rooms.