EN-4EN-3
2
EN
Accessory parts and Parts to be procured locally
Accessory parts
Part name
Q'ty RBM-Y0611
Shape Usage
F4PUL F6PUL
Installation Manual 1 1 This manual This manual for installer.
Heat insulating pipe
Ø1.9" (Ø48) 4 6
For liquid pipe of indoor unit connection
Ø2.2" (Ø55) 4 6 For gas pipe of indoor unit connection
Attached pipe
Ø3/8" - Ø1/4"
(Ø9.5 - Ø6.4)
46
For liquid pipe of indoor unit connection
Ø5/8" - Ø1/2" - Ø3/8"
(Ø15.9 - Ø12.7 - Ø9.5)
4 6 For gas pipe of indoor unit connection
Attached pipe for
main-pipe
Ø1-1/2" - Ø1-5/8"
(Ø38.1 - Ø41.3)
11
For suction gas pipe of outdoor unit
connection
Ø1-1/2" - Ø1-3/8"
(Ø38.1 - Ø34.9)
11
Ø1-1/2" - Ø1-1/8"
(Ø38.1 - Ø28.6)
11
Ø1-1/2" - Ø7/8"
(Ø38.1 - Ø22.2)
11
Ø1-1/2" - Ø5/8"
(Ø38.1 - Ø15.9)
11
Ø1-1/8" - Ø1-3/8"
(Ø28.6 - Ø34.9)
11
For discharge gas pipe of outdoor unit
connection
Ø1-1/8" - Ø7/8"
(Ø28.6 - Ø22.2)
11
Ø1-1/8" - Ø3/4"
(Ø28.6 - Ø19.1)
11
Ø1-1/8" - Ø1/2"
(Ø28.6 - Ø12.7)
11
Ø7/8" - Ø3/4"
(Ø22.2 - Ø19.1)
11
For liquid pipe of outdoor unit connection
Ø7/8" - Ø5/8"
(Ø22.2 - Ø15.9)
11
Ø7/8" - Ø1/2"
(Ø22.2 - Ø12.7)
11
Ø7/8" - Ø3/8"
(Ø22.2 - Ø9.5)
11
Part name
Q'ty RBM-Y0611
Shape Usage
F4PUL F6PUL
Binding band (L11.8" (L300)) 2 2
For xing heat insulation of exible hose
Binding band (L11.8" (L300)) 22 30 For xing heat insulating pipes
Binding band (L3.9" (L100)) 5 7 For xing clamp lters
Clamp lter 5 7
For reducing electrical noise of
communication wires and oat switch wire
of drain pump (locally procured)
Cable clamp 5 7
For xing indoor unit communication cables
Flexible hose 1 1 For adjustment of drain pipe centering
Hose band 2 2 For connecting drain pipe
Heat insulator 1 1 For insulating drain connecting section
Flat washer (3/8"(M10)) 8 8
M0.4" × Ø1.3"
(M10 × Ø34)
For hanging the unit
Rubber bushing 1 1
For protection of edge at oat switch
of drain pump (locally procured) cable
taking-port
Stopper pipe
Ø3/8" (Ø9.5) 3 5 For liquid pipe of indoor unit connection
Ø5/8" (Ø15.9) 3 5 For gas pipe of indoor unit connection
Heat insulator for
stopper pipe
Ø7/8" (Ø22) 3 5
For liquid pipe of indoor unit connection
Ø1.4" (Ø36) 3 5 For gas pipe of indoor unit connection
Ø1.9" (Ø48) 1 1 For liquid pipe of outdoor unit connection
Ø2.2" (Ø55) 1 1
For discharge gas pipe of outdoor unit
connection
Ø2.5" (Ø63) 1 1
For suction gas pipe of outdoor unit
connection