Loosen 1 screw [1] on the fuser unit front guide rail. Remove 1 screw [2] and replace it in the
adjustment hole [3]. Move the fuser unit front guide rail up or down (one step).
• 0.5 mm scale [4]
Move the fuser unit guide rail upward Move the fuser unit guide rail downward
The reproduction ratio in the secondary
scanning direction on the front side
becomes large.
The reproduction ratio in the secondary
scanning direction on the front side
becomes small.
Before
adjustment
After
adjustment