EasyManua.ls Logo

Toshiba e-STUDIO353 - Page 252

Toshiba e-STUDIO353
302 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13 - 14
13
e-STUDIO350/352/353/450/452/453
FUSER UNIT / PAPER EXIT SECTION
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
(2) IH error
(2) IH error
Initial abnormality:
CPU (IH) abnormality is not cleared.
IH power voltage abnormality:
The input voltage becomes above 20% (approx.) or below 20% (approx.) of the rated voltage.
IGBT high temperature abnormality:
Overheating of IGBT or short- or open-circuit of IGBT temperature-detecting sensor.
IH circuit abnormality:
Abnormality in IH circuit
IH coil abnormality:
Temperature-detecting sensor in IH circuit is abnormal, or IH coil is open-circuited or wrongly in
-
stalled.
Checking timing Error content
Port input value
Error
code
Counter
H1ERR1 H1ERR2
Power ON Initial abnormality
L L C470 10
In warming up IH power voltage abnormality
L L C470 11
Detecting 40°C
IGBT high temperature abnormality
Continuous energization (15 sec.)
L H C480 12
IH circuit/coil abnormality
H H C490 13
In warming up
Detecting 40°C
During ready status
IH power voltage abnormality
L L C470 14
IGBT high temperature abnormality
Continuous energization (15 sec.)
L H C480 15
IH circuit/coil abnormality
H H C490 16
During ready status
During printing
At Energy Saving
Mode
IH power voltage abnormality
L L C470 17
IGBT high temperature abnormality
Continuous energization (15 sec.)
L H C480 18
IH circuit/coil abnormality
H H C490 19
Normal
H
L -
-

Table of Contents