e-STUDIO5506AC/6506AC/7506AC (Ver01) © 2016, 2017 TOSHIBA TEC CORPORATION All rights reserved
2-36
2. Copier-specific Adjustments
(4) Select [05 ADJUSTMENT MODE]. Change the values for codes [7190] to [7192] to adjust the gamma
balance in each of the low- and medium-density area.
Subcode Recommended value
Set a value smaller than
128.
0 to 255 128
* Set the value in increments of approximately 20, while checking the copy image until the optimum value is
obtained. (Note that gradations (density level) in the medium- and high-density areas may be reversed with
some setting values.)
* Since the subcode varies according to the area where the density is adjusted, refer to the table below and
set the appropriate subcode. Remember that mainly adjusting the low- or medium-density area will change
the copy density of the images seen through the back of the page. Setting “2” for the subcode will allow
you to adjust the high-density area. But this will not solve the problem. Therefore, never change the value
for the high-density area.
Area where the density is adjusted
Caution after the adjustment
The adjustment may possibly cause text handwritten with a pencil or light text to become illegible on the copy.
Therefore, carefully perform the adjustment, while checking the copy image.
Remarks
Enter a value within the recommended value range mentioned in the procedures. Otherwise, it may cause a loss
in MFP performance, including degradation in the image quality and a reduction in the life of the consumables.