e-STUDIO5506AC/6506AC/7506AC (Ver01) © 2016, 2017 TOSHIBA TEC CORPORATION All rights reserved
2-44
2. Copier-specific Adjustments
(3) Select [05 ADJUSTMENT MODE]. Change the values for codes [7056] to [7058], [7061], [7249], [7794] to
[7800] and [7801] to [7806] to adjust the default value for the sharpness intensity.
* Increasing the sharpness intensity will enhance the edges of the image.
Color mode Original mode [05] code
Recommended
value
* The smaller the setting value is, the weaker the sharpness intensity becomes. The larger the setting value is,
the stronger the sharpness intensity becomes.
Changing the values for these codes will change the sharpness intensity, when the “Sharpness” indicator in
the “IMAGE” menu is set to the center. Remember that 1 step of the indicator will increase or decrease the
sharpness intensity by 25. If the sharpness intensity of the center value is changed, each step of the
indicator will be changed accordingly. (For instance, if the center value is increased by 25 (sharper), the
value of each step of the indicator will also be increased by 25 (sharper).)
However, the range of adjustment values that is valid for sharpness level change is from -100 to +100 of
the total of the setting value of the [05] code and that of the indicator. For instance, if the setting value of
the [05] code is “153” (+25 from the default value), the limit of the steps in the sharp side of the indicator
is “+3”. If the step is set at “+4”, the image quality will not be changed.
Since "+25" is assigned to the center, the image quality
remains the same even if the indicator is changed from
"+3" to "+4".