EasyManua.ls Logo

Toshiba E-STUDIO850 - Adjustment of Hole Punch Unit

Toshiba E-STUDIO850
592 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
March 2005 © TOSHIBA TEC e-STUDIO520/600/720/850 ADJUSTMENT
3 - 77
3
3.14 Adjustment of Hole punch unit
3.14.1 Sensor output adjustment
Perform this adjustment when the punch driver PCB, transmission sensor (photosensor PCB/LED
PCB) or reflection sensor (scrap full detection PCB unit) has been replaced.
(1) Remove the rear cover of the finisher unit.
(2) Set bits 1 through 6 of DIPSW3 on the finisher controller PCB as indicated.
Fig.3-89
(3) Press SW1 on finisher controller PCB. Pressing this switch automatically adjusts sensor output.
(4) Set all bits on DIPSW3 to OFF
ON
1 2 3 4 5 6 7 8

Table of Contents

Other manuals for Toshiba E-STUDIO850

Related product manuals