March 2005 © TOSHIBA TEC e-STUDIO520/600/720/850 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 13
2
CC50 Finisher related
service call
Horizontal registration motor abnormality: The horizontal
registration motor does not run normally or the puncher
does not move normally.
Ch.5.1.12
CC60 Punch motor abnormality: The punch motor does not run
normally or the puncher does not move normally.
Ch.5.1.12
CCC1 Communication error between Inserter Unit and Finisher Ch.5.1.12
CCD1 Inserter EEPROM abnormality Ch.5.1.12
CCE1 Inserter fan motor abnormality Ch.5.1.12
CD00 Laser optical unit
related service call
Laser initialization time-out: Laser control does not end
within the initialization period.
[e-STUDIO850]
Ch.5.1.11
CD10 Process related
service call
Cleaning brush drive motor abnormality: The cleaning
brush drive motor does not run normally when the power
is turned ON or the copying is started.
Ch.5.1.13
CD20 Used toner transport motor abnormality: The used toner
transport motor does not run normally when the power is
turned ON or the copying is started.
Ch.5.1.13
CD30 Recycle toner transport motor abnormality: The recycle
toner transport motor does not run normally when the
power is turned ON or the copying is started.
Ch.5.1.13
CD40 Toner bag full Ch.5.1.13
CD50 Fuser unit related
service call
Web motor signal path abnormality Ch.5.1.8
CE50 Image quality con-
trol related service
call
Temperature/humidity sensor abnormality: The output
value of the temperature/humidity sensor is out of the
specified range.
Ch.5.1.13
CE90 Drum thermistor abnormality: The output value of the
drum thermistor is out of the specified range.
Ch.5.1.13
CF70 Process related
service call
New toner transport motor abnormality: The new toner
transport motor does not run normally when new toner is
supplied.
Ch.5.1.13
CF80 Hopper motor lockup: The hopper motor does not run
normally when the power is ON or the copying is started.
Ch.5.1.13
F070 Communication
related service call
Communication error between System-CPU and Engine-
CPU
Ch.5.1.9
F090 Other service call SRAM abnormality on SYS board Ch.5.1.13
F091 FRAM abnormality on SYS board Ch.5.1.13
F092 SRAM and FRAM abnormality on SYS board Ch.5.1.13
F100 HDD format error: The HDD cannot be formatted nor-
mally.
Ch.5.1.13
F101 HDD unmounted: Connection of the HDD is not detected. Ch.5.1.13
F102 HDD boot error: HDD does not become ready for booting. Ch.5.1.13
F103 HDD data transfer time-out: Data reading or writing is not
executed in a specified period of time.
Ch.5.1.13
F104 HDD data error: Abnormality is detected in the data of the
HDD.
Ch.5.1.13
F105 Other HDD errors Ch.5.1.13
F106 Point and Print partition damage Ch.5.1.13
F107 /BOX partition damage Ch.5.1.13
F108 /SHA partition damage Ch.5.1.13
F110 Communication
related service call
Communication error between System-CPU and Scan-
ner-CPU
Ch.5.1.9
F111 Scanner response abnormality Ch.5.1.9
F120 Other service call Database abnormality: Databases do not run normally. Ch.5.1.13
F130 Invalid MAC address Ch.5.1.13
F200 Data overwrite kit (GP-1060) is taken off Ch.5.1.13
Error code Classification Contents Troubleshooting