62 Q9 ASD Installation and Operation Manual
Type Reset
Program Utility Group
This feature assists the user when performing fault analysis or by allowing a quick
system setup change when required. Performing a Type Reset results in one of the
following user-selected post-reset configurations.
Settings:
0 — None
1 — 50 Hz Setting
2 — 60 Hz Setting
3 — Reset to Factory Settings
4 — Clear Past Trips
5 — Clear Run Timer
6 — Initialize Typeform
7 — Save User Settings
8 — Restore User Settings
9 — Clear Cumulative Fan Timer
10 — Accel/Decel Time Setting 0.01 – 600.0 Seconds
11 — Accel/Decel Time Setting 0.1 – 6000.0 Seconds
Direct Access Number — F007
Parameter Type — Selection List
Factory DefaultNone
Changeable During Run — No
Forward/Reverse Run Selection
No Path — Direct Access Only
While operating using the keypad (F003 is set to Panel Keypad) this parameter
sets the direction of motor rotation. This setting may be changed during operation.
This setting will not override parameter F311 (Forward/Reverse Disable).
If either direction is disabled via parameter F311, the disabled direction will not
be recognized if commanded by the keypad. If both directions are disabled via
parameter F311, the direction command from the keypad will determine the
direction of the motor rotation.
Settings:
0 — Forward
1 — Reverse
2 — Forward (EOI-Switchable F/R)
3 — Reverse (EOI-Switchable F/R)
Direct Access Number — F008
Parameter Type — Selection List
Factory DefaultForward
Changeable During Run — Yes
Reset
F007 F008