Q9 ASD Installation and Operation Manual 67
Preset Speed 3
Program Preset Speeds
This parameter assigns an output frequency to binary number 0011 and is
identified as Preset Speed 3. The binary number is applied to S1S4 of the
Terminal Board to output the Preset Speed (see F018 for more information on
this parameter).
Direct Access Number — F020
Parameter Type — Numerical
Factory Default0.0
Changeable During Run — Yes
Minimum — Lower-Limit (F013)
Maximum — Upper-Limit (F012)
Units — Hz
Preset Speed 4
Program Preset Speeds
This parameter assigns an output frequency to binary number 0100 and is
identified as Preset Speed 4. The binary number is applied to S1 – S4 of the
Terminal Board to output the Preset Speed (see F018 for more information on this
parameter).
Direct Access Number — F021
Parameter Type — Numerical
Factory Default0.0
Changeable During Run — Yes
Minimum — Lower-Limit (F013)
Maximum — Upper-Limit (F012)
Units — Hz
Preset Speed 5
Program Preset Speeds
This parameter assigns an output frequency to binary number 0101 and is
identified as Preset Speed 5. The binary number is applied to S1S4 of the
Terminal Board to output the Preset Speed (see F018 for more information on
this parameter).
Direct Access Number — F022
Parameter Type — Numerical
Factory Default0.0
Changeable During Run — Yes
Minimum — Lower-Limit (F013)
Maximum — Upper-Limit (F012)
Units — Hz
Preset Speed 6
Program Preset Speeds
This parameter assigns an output frequency to binary number 0110 and is
identified as Preset Speed 6. The binary number is applied to S1S4 of the
Terminal Board to output the Preset Speed (see F018 for more information on
this parameter).
Direct Access Number — F023
Parameter Type — Numerical
Factory Default0.0
Changeable During Run — Yes
Minimum — Lower-Limit (F013)
Maximum — Upper-Limit (F012)
Units — Hz
Preset Speed 7
Program Preset Speeds
This parameter assigns an output frequency to binary number 0111 and is
identified as Preset Speed 7. The binary number is applied to S1S4 of the
Terminal Board to output the Preset Speed (see F018 for more information on
this parameter).
Direct Access Number — F024
Parameter Type — Numerical
Factory Default0.0
Changeable During Run — Yes
Minimum — Lower-Limit (F013)
Maximum — Upper-Limit (F012)
Units — Hz
Preset Speed
3
F020 F024