Note:
Connect the indoor and outdoor units with a
connective cable over the shortest distance as
possible.
Fig. 3-4
3. CAUTION IN INSTALLATION
3-1. Installation of Indoor Unit
3-1-1. Removing the Front Panel
(1) Open the screw caps and remove the two screws
securing the front panel.
Fig. 3-1 Opening the screw cap
(2) Close the screw caps as behind.
(3) Open the air outlet direction (up-down) louver hori-
zontally by hand.
(4) Slightly open the lower part of the front panel,
then pull the upper part of the front panel toward
you to remove it from the rear plate.
Fig. 3-2 Removing the front panel
Caution When Connecting the Connecting Cable
When connecting the connective cable, follow the
instructions below.
(1) Remove the front panel.
Fig. 3-3
Open it upward b
y
putting your finger
on the edge.
(4)
(3)
(2)(1)
(1)(2)
(4)
Air outlet direction
louver.
Front panel
Cord clamp
Wiring cover
Screw
Rear plate
Screws
Rear plate
busing
(1)
(3)
(4)
(2)
70mm
10mm
Grounding wir
e
10mm
50mm