– 9 –
(2) Insert the connective cable fully into the termi-
nal block and secure it by screw tightly.
(3) Secure the connective cable with the cord clamp.
(4) Tightening torque should be 1.2 N.m (12 kgf.cm)
Fig. 3-5
(5) Fix the wiring cover, rear plate bushing and front
panel on the indoor unit.
Fig. 3-6
3-1-2. Caution in Mounting the Front Panel
When the panel is removed and mounted again, fol-
low the step described below.
(1) After fastening two screws, be sure to hook the
inside clicks (1) and (2) of the front panel shown
in Fig. 3-7, right gap is left between the front panel
and the rear plate.
Fig. 3-7
Note:
If cooling (dry) operation is made without push-
ing the air outlet, dew can be attached on the
front panel surface. In addition, a gap between
the front panel and the body will become wider,
spoiling the appearance.
3-1-3. Precautions for Refrigerant Piping
(1) Under-side connection with piping
Fig. 3-8
(1) Cut out the knockout piece from the right below
of the rear plate with a knife, etc. Smooth the cut
edge.
(2) Set the drain hose in the inner part of the indoor
unit and connecting cable in lower part of it.
(3) Wind the tape round them.
Fig. 3-9
Connecting cable
Cord clamp
Screw
Cord clamp
Screws
Wiring cove
r
Grounding wire
Connecting
cable
1
2
3
4
(1) (2)
Push Push
Slit part
Rear plate
Pipe holder
Pipe holder
Indoor unit
Piping
Connectin
g
cable
Drain hose
W
all
Installation plate