FILE NO. SVM-02003
– 11 –
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit
4-2. Outdoor Unit (RAS-13UAX-T2)
No. Parts name Type Specifications
Output (Rated) 1100W, 2poles, 1 phase, 220 – 240V, 50Hz
1 Compressor RM5515FNE96 Winding resistance (Ω) C-R C-S
(at 20°C) 2.43 3.78
Output (Rated) 42W, 6poles, 1 phase, 220 – 240V, 50/60Hz
2 Fan motor (for outdoor) HF-240-42B Winding resistance (Ω) Red-Black White-Black
(at 20°C) 176.2 290.5
3
Running capacitor
DS451205BPQA AC 450V, 2.0µF
(for fan motor)
4
Running capacitor
DS371306CPNB AC 370V, 30µF
(for compressor)
5 Overload relay LAAO00A U/T: 9.0A (80°C), OPEN: 135±5°C, CLOSE: 75±11°C
No. Parts name Type Specifications
1 Fan motor (for indoor) MMF-240-20-4A-1 AC Motor with 135°C thermo fuse
2 Thermo sensor (TA-sensor) ——— 10kΩ at 25°C
3 Switching transformer (T01) SWT-47
4 Microcontroller unit (IC30) TMP87CM40AN-2C67
5 Heat exchanger sensor
——— 10kΩ at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB01) D3SBA60 4A, 600V
8 Capacitor (C02) KMH400VSSN47M22S 47µF, 400V
9 Fuse (F01) TSCR6.3A T6.3A, 250VAC
10 Varistor (R21, R22) 15G561K 560V
11 Resistor (R01) RF-2TK5R6 5.6Ω, 2W
12 Louver motor MP24GA 12VDC
13 Relay (Comp., RY01) DI12D1 Rating 20A/AC250V, 12VDC