FILE NO. SVM-02003
– 14 –
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Standard 0.48 13.0 High 27/19 35/24
Cooling Overload 0.60 18.0 High 32/23 43/26
Low temperature 0.42 2.0 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
5. REFRIGERATION CYCLE DIAGRAM
5-1. RAS-13UKPX-T2 / RAS-13UAX-T2
Heat exchanger
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
Capillary tube
1.7x500S
RM5515FNE96
Cooling
Mark( )means check points of Gas Leak.
O.D.:12.7mm O.D.:6.35mm
Cooling
Packed valve
(12.7)
Packed valve
(6.35)
0.39m
(Connecting pipe)
12.7
0.49m
(Connecting pipe)
6.35
T1
P
Refrigerant
R-22 : 0.80 kg.