61
FILE NO. SVM-02003
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC
supply.
2) Remove Electric parts cover.
(2-Screws 4 x 10L)
3) Remove the cord clamp (2-Screws 4 x 22
L
)
and disconnect the connecting cable.
4) Remove the front cabinet.
(7-Screws 4 x 10L with nylon washer)
Pull the front lower portion toward you, and
remove it pulling out upward.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor band.
(1-Screw 4 x 10L)
3) Disconnect the lead wires.
1) Perform the common procedure 1.
2) Remove the fixing screw .
(1-Screw 4 x 10L)
3) Disconnect the lead wires.
1) Perform the common procedure 1.
2) Remove the terminal cover of compressor.
3) Remove the overload relay holder and pull up
the overload relay.
4) Disconnect the lead wires.
10-2. Outdoor Unit (RAS-13UAX-T2, RAS-13UAX)
1 Common
procedure
2 Capacitor for
compressor
3 Capacitor for
fan motor
4 Overload relay
Remove
7-Screws 4 x 10L
RAS-13UAX
Overload relay
RAS-13UAX-T2
No. Part name Procedures Remarks
Overload relay
2-Screws 4 x 22L
2-Screws 4 x 10L
For fan motorFor compressor