63
FILE NO. SVM-02003
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC
supply.
2) Remove packed valve cover and electric
parts cover.
(2-Screws 4 x 10L)
3) Remove the cord clamp (2-Screws 4 x 22L)
and disconnect the connecting cable.
4)
Remove the upper cabinet (4-Screws 4 x 10
L
)
Pulling out upword.
5) Remove the front cabinet.
(7-Screws 4 x 10L)
Pull the front right portion toward you, and
remove it pulling out upward.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor
band.
(1-Screw 4 x 10L)
3) Disconnect the lead wires.
1) Perform the common procedure 1.
2) Remove the fixing screw.
(1-Screw 4 x 10L)
3) Disconnect the lead wire
1) Perform the common procedure 1.
2) Remove the terminal cover of compressor.
3) Remove the overload relay holder and pull up
the overload relay.
4) Disconnect the lead wires.
10-4. Outdoor Unit (RAS-07UAX-T2, RAS-10UASX)
1 Common
procedure
2 Capacitor for
compressor
3 Capacitor for
fan motor
4 Overload relay
No. Part name Procedures Remarks
2-Screws 4 x 22L
2-Screws 4 x 10L
For compressor
For fan motor
Overload relay

Table of Contents