EasyManua.ls Logo

Toshiba RAS-07UKPX-T2 - Outdoor Unit (RAS-10 UAX-T2)

Toshiba RAS-07UKPX-T2
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62
FILE NO. SVM-02003
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC
supply.
2) Remove Electric parts cover.
(2-Screws 4 x 10L)
3) Remove the cord clamp (2-Screws 4 x 22L)
and disconnect the connecting cable.
4) Remove the front cabinet.
(7-Screws 4 x 10L with nylon washer)
Pull the front lower portion toward you, and
remove it pulling out upward.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor
band.
(1-Screw 4 x 8L)
3) Disconnect the lead wires.
1) Perform the common procedure 1.
2) Remove the fixing screw.
3) Disconnect the lead wires.
1) Perform the common procedure 1.
2) Remove the terminal cover of compressor.
3) Remove the overload relay holder and pull
up the overload relay.
4) Disconnect the lead wires.
10-3. Outdoor Unit (RAS-10UAX-T2)
1 Common
procedure
2 Capacitor for
compressor
3 Capacitor for
fan motor
4 Overload relay
Remove
7-Screws 4 x 10L
2-Screws 4 x 22L
2-Screws 4 x 10L
For compressor
For fan motor
Overload relay
No. Part name Procedures Remarks

Table of Contents

Related product manuals