4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-10GKHP-E, RAS-07GKHP-E)
No. Parts name Type Specifications
1 Fan motor (for indoor) MMF-240-20-4B AC Motor with 135 °C thermo fuse
2 Thermo sensor (TA-sensor) 10k at 25 C
3 Micro power module (M01) RM1260V
4 Microcontroller unit (IC30) TMP87CM40AFG-6G61
5 Heat exchanger sensor
10k at 25 C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB01) D3SBA60 4A, 600 V
8 Capacitor (C63) EKMH401VSN470MP20S 47mF, 400 V
9 Fuse (F01) BET6.3A 6.3A, 250VAC
10 Varistor (R21, R22) TND15G-561KB0SLAA0 560 V
11 Resistor (R319) RF-2TK5R6 5.6 , 2 W
12 Louver motor MP24ZT 12VDC
13 Relay (Comp., RY01) G4A-1A-E Rating 20A/AC250 V, 12VDC
14 Relay (Fan, RY03) G5NB-1A Rating 3A/AC250 V, 12VDC
15 Relay (Solenoide, RY04) G5NB-1A Rating 3A/AC250 V, 12VDC
W
W
W
°
°
FILE NO. SVM-06037
4-2. Outdoor Unit (RAS-10GAH-E)
SKF-240-20B
No.
235.2 260.1
Parts name Type Specifications
Output (Rated) 1000 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
1 Compressor PH180X1C-4DZDN3 Winding resistance ( ) C-R C-S
(at 20 C) 3.33 3.78
Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
2 Fan motor (for outdoor) Winding resistance ( ) Red-Black White-Black
(at 20°C
3
Running capacitor
DS451155NPQB AC 450 V ~, 1.5mF
(for fan motor)
W
W
°
4
Running capacitor
RS44B256U0213S AC 440 V ~, 25mF
(for compressor)
5 Overload relay JMRA99208-9102 U/T : 4.2A (80°
C), OPEN :
135±5°C, CLOSE : 69±11°C