FILE NO. SVM-06037
5-5. RAS-10GKPX / RAS-10GAX
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Heat exchanger
Propeller fan
Outdoor unit
PH150X1C-4DZDN3
Cooling
Mark ( ) means check points of Gas Leak.
O.D.:9.52 mm O.D.:6.35 mm
Cooling
Packed valve
(Æ9.52)
Packed valve
(Æ6.35)
0.39 m
(Connecting pipe)
Æ9.52
0.49 m
(Connecting pipe)
Æ6.35
T1
P
Refrigerant
R22 : 0.75 kg.
Heat exchanger
Capillary tube
Æ1.5 x 1200l
Ambient temp.
conditions DB/WB
C)
Indoor Outdoor
Standard 0.50 11.0 High 27/19 35/24
Cooling Overload 0.60 16.0 High 32/23 43/26
Low temperature 0.45 2.0 Low 21/15 21/15
Standard
pressure
P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe
T1
(°C)
Fan speed
(indoor)
50Hz
Note
· Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
RAS-10GKPX-V / RAS-10GAX-V
- 19 -