– 3 –
FILE NO. SVM-06037
RAS-10GKHP-E/ RAS-10GKP-E/ RAS-10GKPX/RAS-10GAX
RAS-10GAH-E RAS-10GA-E RAS-10GKPX-V/RAS-10GAX-V
ITEM Cooling Heating Cooling Cooling
Capacity
220V 240V 220V 240V 220V 240V 220V 240V
kW 2.65 2.70 2.95 3.00 2.60 2.60 2.60 2.60
Phase 1∅
Power source V 220 − 240
Hz 50
Power consumption kW 0.93 0.98 0.84 0.86 0.78 0.82 0.78 0.82
Power factor % 97 94 94 91 98 96 98 96
Running Indoor A 0.15
current Outdoor A 4.38 4.34 4.05 3.92 3.45 3.41 3.45 3.41
Starting current A 19 15
Moisture removal lit/h 1.2
Noise Indoor (H/M/L) dB 39/35/31
Outdoor (220-240V) dB
Refrigerant
Name of refrigerant R-22
Rated amount kg 0.67 0.75
Refrigerant control Capillary tube
Gas side size mm 9.52
Connection type Flare connection
Liquid side size mm 6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
m 10*
1
(One way)
Maximum height
m 5
difference
INDOOR UNIT RAS-10GKHP-E RAS-10GKP-E RAS-10GKPX, RAS-10GKPX-V
Height mm 250
Dimensions Width mm 740
Depth mm 185
Net weight kg 8
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 540 560 540
Airflow volume Medium fan m
3
/h 460 520 460
Low fan m
3
/h 340 400 340
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-10GAH-E RAS-10GA-E RAS-10GAX, RAS-10GAX-V
Height mm 550
Dimensions Width mm 780
Depth mm 185
Net weight kg 31 30
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 1740 1850 1740 1850 1740 1850 1740 1850
Fan motor output W 20
Compressor
Model PH180X1C-4DZDN3
Output W 605
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 −10 ~ 24 21 ~ 43
MODEL
47
49 47
49
44 45
44
45
1. SPECIFICATIONS
∅
∅
PH150X1C-4DZDN3
605
15 ~ 43